and the motor cannot be switched from forward to reverse unless the stop switch is pressed first.
Notes
Except for the back emf diodes across the relay coils this circuit is identical in function to the example shown on the
relay contact labeling guide in the practical section. At first glance this may look
over-complicated, but this is simply because three non-latching push button switches are used. When the forward
button is pressed and released the motor will run continuously in one direction. The Stop button must be used before
pressing the reverse button. The reverse button will cause the motor to run continuously in the opposite direction, or
until the stop button is used. Putting a motor straight into reverse would be quite dangerous, because when running a
motor develops a back emf voltage which would add to current flow in the opposite direction and probably cause arcing
of the relay contacts. This circuit has a built-in safeguard against that condition.
Circuit Operation
Assume that the motor is not running and that all relays are
unenergized. When the forward button is pressed, a positive battery is
applied via the NC contacts of B1 to the coil of relay RA/2. This will
operate as the return path is via the NC contacts of D1. Relay RA/2 will
operate. Contacts A1 maintain power to the relay even though the
forward button is released.
Contacts A2 apply power to the motor which will now run continuously in
one direction. If now the reverse button is pressed, nothing happens
because the positive supply for the switch is fed via the NC contact
A1, which is now open because Relay RA/2 is energized. To Stop the
motor the Stop switch is pressed, Relay D operates and its contact D1
breaks the power to relays A and B, (only Relay A is operated at the
moment). If the reverse switch is now pressed and released. Relay B
operates via NC contact A1 and NC contact D1. Contact B1 closes and
maintains power so that the relay is now latched, even when the reverse
switch is opened. Relay RC/2 will also be energized and latched.
Contact B2 applies power to the motor but as contacts C1 and C2 have
changed position, the motor will now run continuously in the opposite
direction. Pressing the forward button has no effect as power to this
switch is broken via the now open NC contact B1. If the stop button is
now pressed. Relay D energizes, its contact D1 breaks power to relay B,
which in turn breaks power to relay C via the NO contact of B1 and of
course the motor will stop. All very easy. The capacitor across relay D
is there to make sure that relay D will operate at least longer than the
time relays A,B and C take to release.
Correction to Diagram
In the original circuit when the Stop switch was pressed, relay RA
remains energized, its holding current path is through relay coils RB
and RC. To fix this relay D has two contacts, D2 now breaks power to the
relay coil. Special thanks to
Joseph Cremona from Malta for pointing this mistake out.
No comments:
Post a Comment